HID ProxPoint® Plus 6005
125 kHz Mini Mullion Proximity Reader
Overiview & Key Features
HID's ProxPoint® Plus reader combines multiple configuration options with an attractive, inconspicuous design and economical price. Its secure potted electronics are ideal for both indoor and outdoor applications.
-
Small sized, low cost reader features a beeper and multicolor LED which can be host and/or locally controlled.
-
Potted reader suitable for indoor or outdoor use.
-
18" (45 cm) wire pigtail standard; consult factory for 9' (2.7 m) pigtail available by special order.
-
Classic Series covers available in black, gray, white or beige. Designer Series covers available in black or gray.
Key Features
-
Features a beeper and multicolor LED which can be hostand/ or locally controlled.
-
Enables various beeper and LED configurations, depending on individual site requirements.
-
Can read HID cards with formats up to 85 bits.
-
Designed for mounting directly onto metal with no change in read range performance.
-
Available with either Wiegand or Clock-and-Data (magnetic stripe data) output.
-
Compatible with all standard access control systems.
-
Aesthetic design available in two cover designs and in four colors to match any decor.
-
Includes multilingual installation manual.
Specifications
Typical maximum* read range
ProxCard® II Card - up to 3" (7.6 cm)
ISOProx® II card - up to 2.5" (6.35 cm)
DuoProx® II Card - up to 2.5" (6.35 cm)
Smart ISOProx®/DuoProx® II Cards - up to 2.5" (6.35 cm)
Proximity & MIFARE® Card - up to 2.5" (6.35 cm)
ProxCard Plus® Card - up to 1.0" (2.5 cm)
ProxKey® II Keyfob - up to 1.5" (3.8 cm)
MicroProx® Tag - up to 2" (5.1 cm)
*Depending on local installation conditions.
Dimensions
3.135" x 1.720" x 0.660" (7.96 x 4.37 x 1.68 cm)
Power Supply
5-16 VDC
Linear power supplies are recommended.
Maximum Current Requirements
Current (DC)
Average 30 mA, Peak 75 mA
Operating Temperature
-22º to 150º F (-30º to 65º C)
Operating Humidity
0-95% relative humidity noncondensing
Weight
2.7 oz. (75 gm)
Current Requirements
20mA avg / 75mA peak at 12VDC
Cable Distance
Wiegand or Clock-and-Data interface:
500 feet (150 m)
Recommended cable is ALPHA 1295 (22 AWG) 5 conductor stranded with overall shield or equivalent.
Certifications
Canada/UL 294 Listed
FCC Certification, United States
Canada Certification
EU and CB Scheme Electrical Safety (EN60950 and IEC60950 ITE Electrical Safety)
Fifteen EU Countries under the R&TTE Directive (EN 300 330 - SRD, and ETS 300 683 - EMC)
CE Mark
Australia C-Tick, New Zealand
Taiwan, China